Sampling of boiler water is a necessity in order to monitor the condition of the water and to apply for a suitable water treatment system. However, since part of the sample is wasted as steam due to the pressure reduction to atmospheric conditions, it cannot provide an accurate measurement of the hardness or TDS of the water. Therefore, it is necessary to use a device similar to a heat exchanger to reduce the temperature of the sample to an acceptable level. STEAMA SSC16 sample cooler with an integrated all-stainless steel structure, using high-pressure coils, provides the possibility of safe and correct sampling.
Steam Asia Company, as the manufacturer of STEAMA products, is proud to provide sales and after-sales engineering services for all products of this brand. In this regard, the following services can be provided by this company:
- Guarantee up to 3 years and after-sales service for 60 months
- Supervising the installation and commissioning procedures
- Providing all spare parts in the shortest time
- Free-of-charge training courses for operating personnel
- The possibility of periodic inspection and testing of installed equipment
-
Body design and material
PN16, Stainless Steel 304
-
Size
½” – Cooling Water ¼” - Sample
-
Maximum design pressure (PMA)
10 bar g
-
Maximum design temperature (TMA)
100 °C
-
Maximum working pressure (PMO)
32 bar g
-
Maximum working temperature (TMO)
239 °C